Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Arq. bras. cardiol ; 119(3): 460-467, set. 2022. ilus, tab
Article in English, Portuguese | LILACS, CONASS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1403349

ABSTRACT

FUNDAMENTO: A incidência de ductus arteriosus patente (PCA) pode chegar a 50% em pacientes prematuros. Quando hemodinamicamente significativo, pode ser responsável por tempo de ventilação mecânica prolongado, além de importante fator de risco para o aparecimento de enterocolite necrotizante, hemorragia intraventricular e displasia broncopulmonar nessa população. OBJETIVO: O objetivo deste estudo é descrever a experiência inicial do fechamento percutâneo de canal arterial em prematuros pesando menos de 2 kg. MÉTODOS: Trata-se de estudo prospectivo que compreendeu 14 pacientes consecutivos submetidos a fechamento percutâneo de canal arterial de março de 2020 a fevereiro de 2021 em 6 instituições no Brasil. RESULTADOS: A idade gestacional média ao nascimento foi de 28,45 ±3,14 semanas, a idade média no momento do procedimento foi de 38,85 ±17,35 dias e o peso médio de 1,41±0,41 kg. Dentre os prematuros, 79% necessitavam de ventilação mecânica e 79% tinham feito uso de, em média, 1,5 ciclos de anti-inflamatórios não esteroides. A maioria dos pacientes teve melhora dos parâmetros ventilatórios e o tempo médio de extubação foi de 12,6 ±7,24 dias. A taxa de sucesso foi de 100%. Não houve mortalidade relacionada ao procedimento. CONCLUSÃO: Este estudo concluiu que o fechamento percutâneo do canal arterial em prematuros é uma realidade no Brasil, com resultados satisfatórios e baixa taxa de complicações.


BACKGROUND: The presence of patent ductus arteriosus can be as high as 50% in preterm babies. Hemodynamically significant patent ductus arteriosus is a common cause of delayed weaning of respiratory support and an important risk factor of necrotizing enterocolitis, intraventricular hemorrhage, and bronchopulmonary dysplasia in this population. OBJECTIVE: The aim of this study is to describe an initial experience of percutaneous closure of the ductus arteriosus in preterm infants weighing less than 2 kg. METHODS: This was a prospective study, comprised of 14 consecutive patients submitted to percutaneous closure of ductus arteriosus between March 2020 and February 2021 in 6 institutions in Brazil. RESULTS: Mean gestational age was 28.45±3.14 weeks, mean age at the procedure was 38.85±17.35 days and mean weight was 1.41 ±0.41 kg; 79% of the patients were under mechanical ventilation, and 79% had been submitted, on average, to a 1.5 cycle of non-steroidal anti-inflammatory drugs. Most patients were weaned off of mechanical ventilation in a mean of 12.6 ±7.24 days after the procedure. Success rate was 100%. No procedure-related mortality was observed. CONCLUSION: This study concluded that percutaneous closure of ductus arteriosus in premature babies below 2 kg has satisfactory results and a low complication rate in this study sample.


Subject(s)
Humans , Infant, Newborn , Ductus Arteriosus , Heart Defects, Congenital , Neonatology , Infant, Newborn , Infant, Premature , Catheterization
6.
Arq. bras. cardiol ; 105(5): 487-492, Nov. 2015. tab, graf
Article in English | LILACS | ID: lil-764993

ABSTRACT

Background:Advantages and disadvantages of ad hoc percutaneous coronary intervention have been described. However little is known about the radiation exposure of that procedure as compared with the staged intervention.Objective:To compare the radiation dose of the ad hoc percutaneous coronary intervention with that of the staged procedureMethods:The dose-area product and total Kerma were measured, and the doses of the diagnostic and therapeutic procedures were added. In addition, total fluoroscopic time and number of acquisitions were evaluated.Results:A total of 568 consecutive patients were treated with ad hoc percutaneous coronary intervention (n = 320) or staged percutaneous coronary intervention (n = 248). On admission, the ad hoc group had less hypertension (74.1% vs 81.9%; p = 0.035), dyslipidemia (57.8% vs. 67.7%; p = 0.02) and three-vessel disease (38.8% vs. 50.4%; p = 0.015). The ad hoc group was exposed to significantly lower radiation doses, even after baseline characteristic adjustment between both groups. The ad hoc group was exposed to a total dose-area product of 119.7 ± 70.7 Gycm2, while the staged group, to 139.2 ± 75.3 Gycm2 (p < 0.001).Conclusion:Ad hoc percutaneous coronary intervention reduced radiation exposure as compared with diagnostic and therapeutic procedures performed at two separate times.


Fundamento:Uma série de vantagens e desvantagens tem sido descrita para a intervenção coronária percutânea ad hoc, como a realizada ao mesmo tempo que o cateterismo diagnóstico, porém pouco se sabe sobre a exposição radiológica desse procedimento, comparado com a intervenção estadiada, ou seja, em dois momentos.Objetivo:Comparar a dose de radiação utilizada na angioplastia ad hoc com a angioplastia estadiada.Métodos:O produto de dose por área e o Kerma total foram mensurados, somando-se ambas as fases de diagnóstico e terapêutica. Além disso, foram computados o tempo total de fluoroscopia e o número de filmagens.Resultados:Um total de 568 pacientes consecutivos foram tratados com intervenção coronária percutânea ad hoc (n = 320) ou estadiada (n = 248). À admissão, o grupo do ad hoc apresentava menos hipertensão (74,1% vs. 81,9%; p = 0,035), dislipidemia (57,8% vs. 67,7%; p = 0,02) e doença triarterial (38,8% vs. 50,4%; p = 0,015). O grupo ad hoc foi exposto a doses significativamente menores de radiação, mesmo após ajuste para as diferenças basais entre os grupos. O grupo ad hoc foi exposto a uma dose de produto de dose por área total de 119,7 ± 70,7 Gycm2 enquanto que os pacientes estadiados foram expostos a uma dose de 139,2 ± 75,3 Gycm2 (p < 0,001).Conclusão:A intervenção coronária percutânea ad hoc reduziu a exposição radiológica, em comparação com procedimentos diagnósticos e terapêuticos realizados em tempos separados.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/methods , Radiation Dosage , Radiation Exposure/prevention & control , Coronary Angiography , Cardiac Catheterization/methods , Drug-Eluting Stents , Fluoroscopy/methods , Prospective Studies , Radiation Monitoring , Risk Factors , Statistics, Nonparametric , Time Factors
7.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 25(3): 141-146, jul.-set. 2015. ilus
Article in Portuguese | LILACS, SES-SP | ID: lil-788855

ABSTRACT

Os avanços na tecnologia nas últimas décadas em relação ao tratamento intervencionista das cardiopatias congênitas têm permitindo excelentes resultados, em termos de morbimortalidade, a curto e longo prazo para este grupo especial de pacientes.Este artigo descreve os principais tratamentos disponíveis realizados com cateterismo intervencionista neste grupo de pacientes.


Technological advances in recent decades, in relation to interventionist treatment of congenital heart defects, have enabled excellent short- and long-term results for this group of patients, in terms of morbidity and mortality. This article describes the main treatmentsavailable involving interventionist catheterization in this group of patients.


Subject(s)
Humans , Male , Female , Child , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/therapy , Catheterization/methods , Indicators of Morbidity and Mortality , Stents , Ductus Arteriosus/surgery , Aortic Coarctation/diagnosis , Aortic Coarctation/therapy , Heart Septal Defects, Atrial/diagnosis , Heart Septal Defects, Atrial/therapy , Echocardiography, Transesophageal/methods , Pulmonary Valve Stenosis/diagnosis , Pulmonary Valve Stenosis/therapy , Prostheses and Implants
9.
Rev. bras. cardiol. invasiva ; 22(3): 271-274, Jul-Sep/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-732788

ABSTRACT

Introdução: O tratamento percutâneo da coarctação da aorta é método de escolha em crianças acima de 6 meses de idade e sem hipoplasia do arco aórtico. No entanto, nos pacientes com menos de 25 kg, a via de acesso clássica (femoral) pode representar um problema, principalmente nos implantes de stents, devido ao tamanho dos introdutores. O objetivo deste estudo foi relatar a experiência com a punção da artéria axilar como via de acesso para o tratamento percutâneo de pacientes com coarctação da aorta e peso < 25 kg. Métodos: A punção foi realizada com agulha 21 G, com o braço abduzido em 90º, sendo introduzido fio-guia 0,014 polegada, posicionado na aorta descendente. Um introdutor 5 F pediátrico de 7 cm foi inicialmente utilizado para realização do procedimento, sendo substituído, quando necessário, por um introdutor maior. Após a intervenção, foi realizada compressão hemostática manual. Resultados: Foram tratadas dez crianças, sendo oito com recoarctação póscirúrgica e duas com coactação nativa, com idades de 51,1 ± 30,8 meses e peso de 15,8 ± 5,8 kg. A punção foi realizada em todos os casos sem dificuldade técnica, e a mediana do calibre do introdutor foi de 7 F. Em oito pacientes, foram implantados oito stents e, em dois, foi realizada apenas angioplastia com balão. Houve sucesso técnico em todos os ...


Background: Percutaneous treatment of aortic coarctation is the method of choice in children over 6 months of age and without aortic arch hypoplasia. However in patients less than 25 kg the classical access route (femoral) may pose a problem, especially in cases of stenting, due to the size of the size of the introducers. The objective of this study was to report our experience with the axillary artery approach for the percutaneous treatmentof patients with aortic coarctation weighing less than 25 kg. Methods: The arterial puncture was performed with a 21 G needle, with the arm abducted at 90º, and a 0.014 inch guidewire was positioned in the descending aorta. A 5 F × 7 cm pediatric introducer was initially used for the procedure and whenever required, it was replaced in a larger one. Manual-compression hemostasis was performed after the intervention. Results: Ten children were treated, eight with residual and two with native coarctation, mean age was 51.1 ± 30.8 months and weight 15.8 ± 5.8 kg. Puncture was performed in all cases without technical difficulty and the median introducer size was 7 F. Eight stents were implanted in eight patients and two patients were only treated by balloon angioplasty. Technical success was observed in all patients. After removal of the introducer, there was no permanent pulse loss and one patient had a small local hematoma. Conclusions: In our experience the axillary artery approach for percutaneous ...

10.
Rev. bras. cardiol. invasiva ; 21(2): 176-187, abr.-jun. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-681952

ABSTRACT

A correção cirúrgica de algumas cardiopatias congênitas complexas envolve a reconstrução da via de saída do ventrículo direito com a interposição de homoenxertos, biopróteses, enxertos de jugular bovina ou outros condutos valvulados entre o ventrículo direito e o tronco da artéria pulmonar. Apesar de essas cirurgias poderem ser realizadas com baixa mortalidade, a vida útil das válvulas ou dos condutos implantados é normalmente pequena (< 10 anos), seja por degeneração e/ou calcificação. Graus variáveis de estenose pulmonar na maioria das vezes associada a insuficiência pulmonar são consequências da degeneração dos condutos. Em 2000, Bonhoeffer et al. foram os primeiros a relatar o implante transcateter de bioprótese valvular pulmonar (ITVP) com um dispositivo que posteriormente foi denominado de válvula Melody® (Medtronic, Minneapolis, Estados Unidos). A técnica foi inicialmente desenvolvida para limitar a necessidade de múltiplos procedimentos cirúrgicos, substituindo, em última análise, uma nova troca cirúrgica valvular. Estudos subsequentes na Europa e Estados Unidos atestaram para a segurança e eficácia dessa técnica em um número maior de pacientes. Como a Agência Nacional de Vigilância Sanitária (Anvisa) concedeu a aprovação para o uso clínico da válvula biológica pulmonar transcateter Melody® em fevereiro de 2013, consideramos necessária e oportuna a avaliação judiciosa da utilização dessa nova tecnologia antes que ela fosse aplicada em larga escala em nosso país. O objetivo deste estudo foi realizar uma revisão sistemática da literatura sobre o ITVP em pacientes com disfunções de homoenxertos, condutos valvulados e biopróteses implantados cirurgicamente na via de saída do ventrículo direito.


Surgical repair of some complex congenital heart diseases involves reconstruction of the right ventricular outflow tract using homografts, bioprostheses, bovine jugular grafts or other valved conduits between the right ventricle and the main pulmonary artery. Although these surgical procedures may be performed with low mortality rates, the life span of these implanted valves or conduits is usually short (< 10 years) due to either degeneration and/or calcification. Variable degrees of pulmonary stenosis, often associated with pulmonary insufficiency, are consequences of conduit degeneration. In 2000, Bonhoeffer et al. were the first to report the transcatheter pulmonary valve implantation (TPVI) of a bioprosthetic pulmonary valve later named Melody® valve (Medtronic, Minneapolis, USA). The technique was initially developed to limit the need for multiple surgical procedures, and, ultimately, to work as a surrogate of a new surgical valve replacement. Subsequent clinical studies in Europe and the United States confirmed the safety and efficacy of this technique in a larger number of patients. Since the National Sanitary Surveillance Agency (Agência Nacional de Vigilância Sanitária - Anvisa) granted approval for clinical use of the Melody® transcatheter pulmonary biological valve in February 2103, we deemed that a judicious assessment of this new technology was timely and necessary before the widespread use in our country. The objective of this study was to perform a systematic literature review on the use of TPVI in patients with dysfunctional homografts, valved conduits and bioprostheses implanted surgically in the right ventricular outflow tract.


Subject(s)
Humans , Cardiac Catheterization/methods , Prostheses and Implants , Heart Valve Prosthesis , Pulmonary Valve/surgery , Heart Defects, Congenital/surgery , Review Literature as Topic
11.
Rev. bras. cardiol. invasiva ; 19(2): 212-217, jul. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-595238

ABSTRACT

O uso de stents intravasculares em crianças com cardiopatia congênita é procedimento bem estabelecido, porém a indicação de paliação por meio de procedimentos percutâneos ao invés da cirurgia convencional permanece incerta. Neste relato são apresentados três casos de obstrução crítica de via de saída do ventrículo direito (VSVD), submetidos a ampliação da VSVD com implante de stent. O implante foi realizado com sucesso nos três casos, permitindo restabelecer o fluxo pulmonar para a árvore pulmonar e melhorar a saturação de oxigênio.


The use of intravascular stents in children with congenital heart disease is well established, however the use of palliative percutaneous therapy instead of a conventional surgery remains uncertain. We present three cases of critical right ventricular outflow tract (RVOT) obstruction treated with stenting to expand the RVOT. Stenting was successful in all three cases, reestablishing pulmonary flow into the pulmonary arteries and improving oxygen saturation.


Subject(s)
Humans , Male , Infant, Newborn , Child, Preschool , Pulmonary Artery/surgery , Ventricular Outflow Obstruction/complications , Stents , Echocardiography/methods , Echocardiography , Tetralogy of Fallot/complications
12.
Rev. bras. cardiol. invasiva ; 18(1): 74-80, mar. 2010. tab, ilus
Article in Portuguese | LILACS | ID: lil-549234

ABSTRACT

INTRODUÇÃO: O forame oval parente ocorre em 27 por cento a 30 por cento da população e pode estar associado a eventos embólicos, dentre eles o acidente vascular cerebral criptogênico. A prótese PREMEREtm. especialmente desenvolvida para a correção do forame oval patente, apresenta baixo perfil, reduzida quantidade de metal e âncora no lado esquerdo, com reduzida superfície para minimizar o risco de formação de trombos. Avaliamos os resultados clínicos e ecocardiográficos imediatos e aos três e seis meses pós-implante do dispositivo. Métodos: Entre maio de 2008 e junho de 2009, a prótese foi implantada em 14 pacientes com forame oval patente e que apresentaram eventos embólicos cerebrais prévios, comprovados por tomografia computadorizada e/ou ressonância nuclear magnética de crânio. O diagnóstico ecocardiográfico de forame oval patente foi realizado quando microbolhas...


BACKGROUND: Patent foramen ovale is observed in 27% to 30% of the population and may be associated to embolic events, among them the cryptogenic stroke. The PREMERE TM device, specially developed to correct patent foramen ovale, has a low profile, reduced amount of metal and a left anchor with a small total surface to minimize the risk of thrombus formation. Clinical and echocardiographic results were evaluated immediately after the procedure and 3 and 6 months after device implantation. METHOD: From May 2008 to June 2009, the device was implanted in 14 patients with patent foramen ovale with prior cerebral embolic events, confirmed by computerized tomography and/or cranial magnetic resonance imaging. Echocardiographic patent foramen ovale was diagnosed when microbubbles were detected in the left atrium within three heartbeats after opacification of the right atrium. Patients with patent foramen ovale with interatrial septal aneurysm > 2 cm, those with atrial fibrilation/flutter or with other diseases that might explain the cryptogenic stroke were excluded. RESULTS: Nine (64.3%) patients were male and mean age was 47.2 ± 17.5 years. Successful implantation was achieved in 100% of the cases. Transesophageal echocardiogram immediately after the procedure showed the presence of microbubbles in the left atrium with Valsalva maneuver in 50% of the cases. All of the patients were discharged the following day, receiving acetyl salicylic acid 200 mg/day and clopidogrel 75 mg/day and returned after 3 months for clinical and echocardiographic follow-up. The transesophageal echocardiogram at three months showed a mild residual flow in only 3 (21.4%) patients. These patients had a totally occluded patent foramen ovale at the 6-month follow-up transesophageal echocardiogram. None of the patients had cardiovascular events during the follow-up period. CONCLUSION: The PREMERE TM device proved to be safe and effective in the occlusion of patent foramen ovale. The occlusion rate in this initial experience was high for a follow-up period of 6 months.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Stroke/complications , Stroke/diagnosis , Pulmonary Embolism/complications , Pulmonary Embolism/diagnosis , Foramen Ovale, Patent/surgery , Prosthesis Design , Echocardiography/methods , Echocardiography
SELECTION OF CITATIONS
SEARCH DETAIL